Airedale by Modine
Modine's UK cooling brand sells in-row CDUs of about 1 MW and a skid CDU of about 2.1 MW, sized at 1.5 l/min per kW.
- Smallest CDU
- 400 kW Airedale CDU brochure (Oct 2025), 9 Nov 2026
- Largest CDU
- 2,160 kW Airedale CDU brochure (Oct 2025), 9 Nov 2026
Rating conditions
Inrow ~1,000–1,028 kW, skid ~2,100–2,160 kW (Global vs NA basis). Overall range stated 400 kW–2 MW+.
Visit Airedale by Modine Compare with alternatives Request a quote
Datasheet
Source on every value- Technologies Liquid cooling product types the vendor sells today. 'Liquid-to-air CDU' is a sidecar unit or heat dissipation unit that needs no facility water. 'Two-phase cold plate' boils a refrigerant or dielectric on the chip.
- CDU 1
- Smallest CDU kW Rated cooling capacity of the smallest shipping CDU in the line, as the vendor publishes it. Rating conditions (approach temperature, fluid) are in the spec notes. Blank when not published.
- 400 2
- Largest CDU kW Rated cooling capacity of the largest shipping CDU, as the vendor publishes it. Prototypes and announced-only units are left out and named in the spec notes. Blank when not published.
- 2,160 2
- GPU platforms (vendor-stated) GPU or rack platforms the vendor itself names as supported, certified or targeted, such as NVIDIA GB200 NVL72 or Vera Rubin. Vendor statements only, each with a source. Blank when the vendor names none.
- Not published
- Level Where the products sit: in the server, in the rack, in the row, or at facility scale (skid or facility distribution unit).
- In-row, Facility 1
- Coolant Coolant on the IT side: water-glycol (PG25 and similar), single-phase dielectric (oils, GTL, synthetic hydrocarbons) or two-phase dielectric or refrigerant.
- Water-glycol 1
- Max per rack kW Highest rack density the vendor publishes for its own system (immersion tank, in-rack CDU, rear door or OEM rack). Filled only when the vendor states a per-rack figure.
- Not published
- Rear door max kW Highest published heat removal of the vendor's rear-door heat exchanger, per rack.
- Not published
- Vendor type Liquid cooling specialist, thermal and HVAC major, power and data center infrastructure major, server OEM, component maker (cold plates, connectors, CDUs sold to OEMs) or fluid supplier.
- Thermal and HVAC major 1
- Parent company Owner or controlling shareholder when the vendor sits inside a larger group, such as CoolIT under Ecolab or Motivair under Schneider Electric.
- Modine 1
- HQ region Region of the vendor's (or brand owner's) headquarters.
- Europe 1
- HQ country Country of the vendor's (or brand owner's) headquarters.
- United Kingdom 1
- Headquarters Headquarters city and country as the vendor states it.
- Leeds, United Kingdom 1
- Manufacturing Regions or sites where the vendor says it builds liquid cooling products. Blank when not published.
- Not published
- Key products Main product lines and model names for data center liquid cooling.
- CDU10/CDU12 in-row, CDU15 skid 1
- Spec notes Rating conditions behind the numbers (approach temperature, water temperature, fluid), conflicting figures, and prototypes left out of the ranges.
- Inrow ~1,000–1,028 kW, skid ~2,100–2,160 kW (Global vs NA basis). Overall range stated 400 kW–2 MW+. 1
Sources
2- Airedale CDU product page accessed 2026-11-09
- Airedale CDU brochure (Oct 2025) accessed 2026-11-09
Airedale by Modine alternatives
Largest CDU- Boyd Thermal (Eaton) 2,300 kW3
- Vertiv 2,300 kW1
- Nidec 2,000 kW1
- nVent 2,000 kW1
- STULZ 2,000 kW2
- ZutaCore 2,000 kW1
See all CDU vendors.
Get quotes from Airedale by Modine and similar vendors
Tell us what you need once. We send it to matching liquid cooling vendors and they reply to you directly.