Immersion cooling companies

Immersion cooling sinks whole servers in a dielectric fluid that carries the heat to a CDU. Single-phase tanks lead on published density: GRC ICEraQ systems run a CDU up to 368 kW with 13 °C water and Submer lists its SmartPod EXO at 280 kW+ per pod. The fluids come from the same tank makers, from specialists such as Engineered Fluids, and from oil and chemical majors: Shell, Castrol, TotalEnergies, Dow and Chemours.

13 vendorsChecked

TechnologiesCoolantLevel
GRC (Green Revolution Cooling)IMM-1φ · Fluid36813681DE-1φIn-rack—North America2026-11-09
SubmerIMM-1φ2801—DE-1φIn-rack—Europe2026-11-09
AsperitasIMM-1φ601—DE-1φIn-rack—Europe2026-11-09
CastrolIMM-1φ · Fluid——WG · DE-1φ———2026-11-09
Chemours (Opteon)IMM-2φ · Fluid——DE-2φ——North America2026-11-09
DCX Liquid Cooling SystemsCDU · IMM-1φ · Manifold · Fluid—8,1502WG · DE-1φIn-rack, In-row, Facility—Europe2026-11-09
DowIMM-1φ · Fluid——WG · DE-1φ——North America2026-11-09
Engineered FluidsIMM-1φ · Fluid——DE-1φ——North America2026-11-09
EnvicoolCDU · D2C · IMM-1φ · Manifold · QD——WG · DE-1φServer, In-rack, In-row, Facility—Asia-Pacific2026-11-09
HypertecIMM-1φ · OEM——DE-1φServer—North America2026-11-09
IceotopeIMM-1φ——DE-1φServer—Europe2026-11-09
Shell (Immersion Cooling Fluids)Fluid——DE-1φ—Shell plcEurope2026-11-09
TotalEnergies FluidsIMM-1φ · Fluid——DE-1φ—TotalEnergiesEurope2026-11-09
Technologies
CDUCoolant distribution unit
D2CDirect-to-chip cold plate
D2C-2φTwo-phase direct-to-chip cold plate
IMM-1φSingle-phase immersion tank
IMM-2φTwo-phase immersion tank
RDHxRear-door heat exchanger
SidecarLiquid-to-air CDU
ManifoldRack and row manifolds
QDQuick-disconnect couplings
OEMServer maker with liquid-cooled racks
FluidCoolant fluid supplier
Coolant
WGWater-glycol
DE-1φSingle-phase dielectric
DE-2φTwo-phase dielectric or refrigerant

Single-phase, two-phase and precision immersion

How ratings are read

Single-phase tanks

The fluid stays liquid. Pumps or natural convection move it past the servers and through a heat exchanger. GRC rates its tanks with coolant near 50 °C, and Asperitas moves the fluid in its PNC tank by natural convection alone. Shell’s gas-to-liquids fluids were the first to be Intel Data Center Certified for immersion.

Two-phase immersion

The fluid boils on the chips and condenses on a coil above the tank. It lost its main fluid when 3M exited Novec. Chemours’ Opteon 2P50 boils at 49 °C with a GWP of 10 and is still labelled developmental; it entered a full-scale trial with NTT DATA in 2025. LiquidStack, a two-phase pioneer, now lists only direct-to-chip CDUs.

Precision immersion

Iceotope seals a small volume of dielectric inside each chassis and pumps it over CPUs, GPUs, memory and power supplies, so servers stay in standard racks. Its KUL AI server is built on a Gigabyte 8-GPU platform.